5 to 10 gallons of sizzling water with restoration occasions starting from 30 to 60 minutes. Burner apparatus including a burner, is disposed in an operative relationship with the heat exchanger for heating water flowing through the heat exchanger. An digital direct spark ignition board and a Gas Regulator with an robotically controlled Dual Solenoid shut-off valve are offered for working the burner apparatus in line with the requirements of the ANSI Z21.10.Three security customary. BTU ranges at completely different water move charges. This feature is achieved utilizing a low value metal disc thermostat to immediately activate the Dual BTU valve without the need of an costly microprocessor control. It is a necessary safety function sometimes called a Limit Switch. An additional safety feature is achieved by incorporating a Relay and a metal disc thermostat on the exhaust housing that cause the induced draft blower to stay operating after every burn until the exhaust housing reaches a low temperature, thus eliminating thermal stress on the heat exchanger and exhaust parts.

FIG. 3 is a perspective view of the Cyber Heater Official Site shown in FIGS. FIG. 4 is one other perspective view of the heater proven in FIGS. FIG. 5 is a functional diagram of the heater shown in FIGS. 10 in accordance with the present invention includes a sealed housing 14 , fabricated from any suitable material equivalent to metallic, which incorporates an air inlet 18 and a flue outlet 22 . 26 features a plenum 30 with surround tubing 34 connected to a chilly-water inlet 36 and a sizzling water outlet 38 . As proven in FIG. 2 , the chilly-water inlet 36 and scorching water outlet 38 lengthen exterior of the sealed housing 14 . Burner apparatus 42 includes a burner forty four which is disposed in an operative relationship with the heat exchanger 26 for heating water flowing through the tubing 34 . 74 additionally screens the flame of the burner forty four verifying the presence of ionization at the situation of a spark igniter 76 and promptly shuts off the fuel move by the use of the twin solenoid valves 54 .

44 , regulator 48 , and solenoid valves 54 are conventional and are available from a number of domestic and foreign suppliers for Cyber Heater Official Site use in traditional gas appliances. BZB02A0502 with Dual BTU choice. An exhaust system fifty eight including a blower 60 with blower motor sixty two , blower relay 64 , ignition relay sixty six , and time delay swap sixty eight (See FIG. 5 ), is provided for inducing draft of air from the air inlet 18 via the heat exchanger 26 and out of the flue outlet 22 . This drastically enhances the effectivity of the burner 44 heat exchanger 26 , and as hereinbefore famous, supplies the efficiency advantages regarding condensation supplies stressing and wind resistance. 74 with a spark igniter 76 which could also be of any authorized standard design certified by an appropriate company (i.

Edit

Pub: 05 Dec 2025 06:11 UTC

Views: 5